This configuration can be used as a reference voltage source and if the used operational amplifier is a high power type, as a high power zener. The circuit is shown in figure bellow and the formula given bellow can be used in practical applications.

 


 

 

 

Formula:

Voltage source:

Vout = - Vz x (R2/R1)

 

Where:

Vout is the output voltage in volts (V)

Vz is the zener voltage

R1 and R2 are the resistances in ohm (Ω)

 

Note: Rz is calculated according the formulas described in the Diode Zener section (formulas 87.x).

 

Application example:

Determine the value for R2 when desiring a reference output voltage of 7 V from a 3 V zener diode in the circuit shown in figure 134. Given R1= 500 Ω.

 

Data:

Vz = 3 V

Vout = 7 V

R1 = 500 Ω

R2 = ?

 

Using formula:

7 = 3 x (R2 / 500)

7 = (3 x R2) / 500

 

Isolating R2:

R2 = (7 x 500) / 3

R2 = 3500 / 3

R2 = 1166 Ω

 